Model No.︰W4-73,W4-72
Brand Name︰linfeng
Country of Origin︰China
Unit Price︰CNY ¥ 36200 / pc
Minimum Order︰1 pc
Centrifugal Fan
Type C6-51
Operation Instruction
LINYI BLOWER WORKS
Purpose
Type 6-51 are mainly used for esporting air mixture with small wood、fiber and dust.
Type
In normal condition, type -51centrifugal fan has 7 different sizes, they are №3.15、№4、№5、№6.3、№8、№10、№12.
One of them can be made of two types rotation i.e. right and left, viewing from one end of the motor, it is called as clockwise fan if the impeller rotates clockwise, and symbolized with “right”, on the contrary, it is called as counter clockwise fan if the impeller rotates counter clockwise, and symbolized with “left”.
The outlet position of the fan can be expressed from the outlet angle of the casing, user can change the angle according to the requirement, without note when ordering.
The outlet is 0°~225°, the interval is 45°;
The mentioned outlet angles is the customary doing of the fan trade, if they can’t meet
your specific environment and condition, our factory can manufacture satisfactory
angles for you, if this situation occurs the installation dimension behind the manual
may be changed, users should take notice.
There are 1 driving modes: C:
C—Cantilever bearing unit, belt driving, but the pulley is outside the bearing;
Generally these driving modes can meet users operating requirement, if they can’t meet your requirement, our factory has ability to design and manufacture satisfactory fan for you.
Structure
The fan mainly consists of impeller, casing, inlet and driving unit, but No. 2.8~6A is mode A driving, and without driving unit.
Impeller—it is the key part of the fan, its material and contour can determine the wind pressure, flow rate, power consumption, noise and service life. The impeller consists of 10 arc blades, a curved front disc and flat rear disc, they are made up of steel plate, 16 Mn stainless steel or glass fiber reinforced plastics according to the various purpose and medium, the impeller shall be balanced statically and dynamically, over speed running test is carried out, and thus it has smooth running and the aerodynamic performance is good.
Casing—it shall be made in integral type, it can not be disintegrated.
Inlet—the inlet is manufactured as an integral type, the section which is parallel to the shaft is curved forms and gas is allowed into the impeller smoothly with a little loss, the inlet is generally fixed on the side of the fan with bolts. Radial and axial clearances between inlet and impeller are too small, friction can be caused between them, and when the clearances are too big, air leakage can be caused between them, please keep the design dimensions.
Driving unit—it consists of shaft, bearing box, rolling bearing, belt pulley .
Performance
The Performance of the fan is symbolized by flow, total pressure, speed, power, efficiency and Parameters etc.. there are certain conversional relations between these parameters, the relation can be shown by performance curve, mathematical formula and form mode etc;
Q—Flow rate m3/h; H—total pressure Pa;
N—Shaft power kW η—total pressure efficiency
ηm—mechanical efficiency % r—specific gravity kg/m3
n—speed r/min; t—temperature ℃
where:
with footnote 2 symbolizes the known parameter,
with footnote 1 symbolizes the unknown parameter.
The performance of the fan normally indicates the performance under the standard state. When the operating condition is inconsistent with standard state, at this moment the Performance must be converted into the performance under the standard state. The so-called standard slate indicates: atmospheric pressure P=101325 Pa, acceleration of gravity g=9.8m/sec2, air density ρ=0.1223kg·sec2/m4, atmospheric temperature t=20℃, the required power N=10-3η-1·K·Q·H, the relative humidity &=50%
Selection of value k
motor power (kW) |
value k |
below 0.5 >0.5~1 >1~2 >2~5 >5 |
1.5 1.4 1.3 1.3 1.15 |
Installation and Operation
First, prepare attachment and tools before installation, then, check every parts of the fan, impeller, casing , shaft and bearing etc. should be inspected carefully, if damages are found, repair should be carried out, and then clean inside of the bearing box with kerosene.
The following points must be noted during installation:
1. Lubricating oil or mechanical oil should be coated on the joint surface in order to prevent rust.
2. When the bolt is screwed in the joint surface, if there are setting dowels, doweling the joint surface first, and then tighten the bolt.
3. Pay attention to check the casing and any tools or goods should not be dropped and remained inside the casing.
Requirements of installation:
1. During installation, prohibit children, old people, disabled person and the persons who has difficulty getting about a bit on the installing site to surround and watch.
2. Install the fan first and then switch on power supply.
3. During installation, the weight of air duct should not added on the casing of the fan.
4. Correct the dimensions between the impeller and the inlet according to the drawing, keep the horizontality of the shaft.
5. When installing the inlet pipe, the bolt of inlet is directly used to connect pipe, at this time the inlet is fixed by three countersunk screws.
6. Turn the rotor with hand or lever after installation to check whether it is over tight or touched with stationary components.
7. After installing the motor, install the belt pulley or coupling guard, if the inlet is not connected to the inlet pipe, the protective net or other safety device is also added (provided by user himself). Other parts of the fan are fixed according to the drawing.
Because of the flow rate Q, total pressure H, the shaft speed n, and shaft power N having the specific relations:
Thus, without changing the motor capacity, the shaft speed can not change, otherwise, the motor may be damaged by overload.
The motor power used by fan indicates under the specific operating condition, shaft power plus mechanical loss and storing quantity, but not the required power when the outlet full open, if the outlet or inlet of fan without connecting pipe or without outside resistance, the motor can not be put into operation. For the safety, a valve should be installed in the inlet and outlet pipes of the fan, close the valve when motor start up, the valve is slowly open after running, until reached the specific operating condition, and pay attention to the current if exceeds the rated value.
Maintenance
2. Maintenance of fan can only be carried out during shut-down of fan.
3. Don’t freely change the maintenance person, specific person operating and repair the fan is preferred.
4. When the fan is repaired, the motor switch must be monitored or locked.
5. Regularly remove dust, contamination and the foreign materials and prevent rust.
6. Inspect the thermometer and oil indicator regularly.
7. Except replacing the lubricant after overall, replace the lubricating oil periodically.
List of troubles and causes
Troubles |
causes |
Severe vibration of bearing box |
1.The shaft of fan is not parallel with that of motor; the coupling is misalignment. 2.friction between casing or inlet and impeller. 3.The foundation is not rigid enough or firm enough. 4.loosing of rivets in impeller or deformation of impeller. 5.Loose matching of shaft with impeller main disc. 6.Loosing of the bolts which connect casing and bearing with support, bearing with its cover. 7.Installation of fan inlet and outlet ducts is improper, which causes vibration. 8.The rotor is unbalance. |
High temperature-rise of bearing |
1.Severe vibration of bearing box. 2.Lubricant is poor in quality, deteriorated, mixed with dust, sand, contamination and etc. 3.Connection of bearing box cover and pedestal is over tight or Loose. 4.Fixing position between shaft and rolling bearing is slant, the front and back bearing are out of alignment. 5.wornout of rolling bearing. |
Over current and high temperature-rise in motor |
1.Gate or damper in the inlet and outlet pipes are not closed when starting-up. 2.Flow rate exceeds the specific value or air duct leaks. 3.Air density delivered by fan is over strong or contain visco-materials. 4.Input voltage of motor is low or is cut out in a single phase. 5.Coupling connecting is out of alignment the belt is too tight or the clearance is not uniform. 6.Influence caused by severe vibration of bearing box. 7.Influence caused by fan in parallel operation condition is worse or trouble happened. |
Belt sliding |
Two belts are not in the center line. The belt slides down from a small belt pulley. |
Bet chattering |
The distance of two belt pulleys is too short or the belt is too long. |
Linyi blower works
Add:hangzhourod.linyi.P.R.china
E-mail:13853987066@163.com
Http:www.sdlyfan.com
Tel: 13853987066